Product Overview
The diesel engine-driven fire pump set is designed and manufactured in accordance with GB standards for fire pumps. It meets CCCF certification requirements. Its advantages include the ability to automatically start and operate when a power failure occurs during a fire, ensuring that fire fighting operations can proceed normally even when electric fire pumps are unable to function. Compared to electric fire pump sets, a second advantage is that it eliminates the need for long-term investment in power supply infrastructure, saving on the costs of power transformers and regular electricity expenses. The diesel engine fire pump set is equipped with various automatic functions to meet customer requirements, ensuring the equipment remains in a ready state for immediate deployment in fire fighting situations. This diesel engine fire pump set is also suitable for various emergency backup pump applications.
Main Features of Diesel Engine Pump Sets
● Automatic Operation: When the diesel engine fire pump set receives a valid fire signal or a remote control start signal, the unit will automatically start and run. If the power supply system of the electric motor fire pump set experiences a power outage or phase loss, the unit will automatically enter standby mode. If the diesel engine fire pump set fails to start within 10 seconds, it will stop for 10 seconds and then restart. The unit will automatically repeat this process three times;
● Automatic Charging: Using mains power for charging, when in automatic standby mode, if the battery voltage is low, the unit will automatically charge. When the battery voltage is sufficient, it will automatically stop charging to prevent damage to the battery;
● Automatic Alarm: Alarms for multiple start failures, low diesel engine oil pressure, high diesel engine water temperature, diesel engine overspeed and shutdown, low battery voltage, charging failure, fuel shortage indication, etc.
● Automatic Preheating: Keeps the diesel engine in a warm standby state to ensure emergency operation;
● Direct Connection: Diesel water pump units below 360kw use the domestically pioneered technology of directly connecting the diesel engine and water pump through an elastic coupling, reducing failure points and significantly shortening the unit's start-up time, increasing the reliability and emergency performance of the unit;
● Users can also request other alarm outputs (non-standard supply);
● Has remote measurement, remote signaling, and remote control functions (non-standard supply);
● Wide range of models: Fire pump sets can use single-stage single-suction pumps, multi-stage single-suction pumps, single-stage double-suction pumps, etc., or a combination of multiple pump types in parallel, with a wide range of flow and pressure.
Operating Conditions
Altitude: ≤2500 meters
Ambient Temperature: -25~55℃
Relative Humidity: ≤95%
Seismic Intensity: 7 degrees
Flow Rate Range: 50-700 (L/S)
Head Range: 32-600m
Diesel Engine Power: 18-1100KW
Material of Wetted Parts: Cast iron, ductile iron, stainless steel, cast copper.
Diesel Engine Brands: Shangchai, Dongfeng, Cummins, Deutz, Fiat Iveco, Wuxi Power, Weichai, etc.
Operating Range
Water supply pressure: 0.2 MPa - 2.5 MPa (20-250 meters)
Flow rate range: 5-1200 L/S
Power: 3 KW - 2000 KW
Rotational speed range: 1500-3200 r/min
Permissible media: Drinking water, chilled water, fire-fighting water, and other media that do not contain abrasive impurities or long fibers, and are not chemically or mechanically corrosive to the pump.
Maximum permissible media temperature: 70℃, maximum ambient temperature: 40℃
Maximum permissible operating pressure: 1.6 MPa, maximum inlet pressure: 0.6 MPa.
Scope of Application
Suitable for various fire hydrants and sprinkler fire main pumps.
Suitable for various fire fighting booster and pressure stabilizing pump applications.
Suitable for fire fighting systems in various villas and residential areas.
Suitable for fire water systems in industrial and civil buildings.
Suitable for applications with high fire safety requirements, such as oil depots, oil loading and unloading terminals, and logistics parks.
Serial Number | Model and specifications | Flow | Pressure | Diesel engine power | Diesel engine speed | Diameter | Price |
L/S | Mpa | Kw | r/min | DN | Yuan | ||
1 | XBC8.5/40G-OHW | 40 | 0.85 | 84 | 1500 | DN150 | 32500 |
2 | XBC7.5/50G-OHw | 50 | 0.75 | 84 | 1500 | DN150 | 32500 |
3 | XBC8.2/50G-OHw | 50 | 0.82 | 100 | 1500 | DN150 | 38500 |
4 | XBC7.0/60G-OHW | 60 | 0.7 | 84 | 1500 | DN150 | 34500 |
5 | XBC8.2/60G-OHw | 60 | 0.82 | 100 | 1500 | DN150 | 38500 |
6 | XBC9.0/60G-OHW | 60 | 0.9 | 100 | 1500 | DN150 | 38500 |
7 | XBC5.0/70G-OHw | 70 | 0.5 | 72 | 1500 | DN200 | 32600 |
8 | XBC6.0/70G-ZWQ | 70 | 0.6 | 84 | 1500 | DN200 | 32500 |
9 | XBC7.0/70G-OHw | 70 | 0.7 | 100 | 1500 | DN200 | 38500 |
10 | XBC8.0/70G-OHW | 70 | 0.8 | 110 | 1500 | DN200 | 40000 |
11 | XBC9.0/70G-OHw | 70 | 0.9 | 121 | 1500 | DN200 | 43000 |
12 | XBC10.0/70G-OHW | 70 | 10 | 132 | 1500 | DN200 | 49500 |
13 | XBC5.0/80G-OHW | 80 | 0.5 | 84 | 1500 | DN200 | 34500 |
14 | XBC6.0/80G-OHW | 80 | 0.6 | 100 | 1500 | DN200 | 38500 |
15 | XBC7.0/80G-OHw | 80 | 0.7 | 132 | 1500 | DN200 | 53000 |
16 | XBC8.2/80G-OHW | 80 | 0.82 | 132 | 1500 | DN200 | 53000 |
17 | XBC5.0/90G-OHW | 90 | 0.5 | 84 | 1500 | DN200 | 34500 |
18 | XBC6.0/90G-OHW | 90 | 0.6 | 100 | 1500 | DN200 | 38500 |
19 | XBC7.0/90G-OHW | 90 | 0.7 | 120 | 1500 | DN120 | 48000 |
20 | XBC8.0/90G-OHW | 90 | 0.8 | 132 | 1500 | DN200 | 56000 |
21 | XBC8.5/90G-OHW | 90 | 0.85 | 132 | 1500 | DN132 | 56000 |
22 | XBC5.0/100G-OHw | 100 | 0.5 | 100 | 1500 | DN200 | 43500 |
23 | XBC6.0/100G-OHW | 100 | 0.6 | 110 | 1500 | DN200 | 45000 |